Mitsubishi FX3U with Weinview HMI: Silo weighing data keeps fluctuating, going crazy

Dear experienced colleagues, here's the situation: We have a packaging machine in our Dongguan factory, using FX3U-48MT with Weinview TK6071iQ, and a load cell connected via FX3U-4AD module for real-time silo weight display. For the past month, the weight value on the screen has been fluctuating irregularly by about ±30g, even though the silo hasn't moved at all. We've replaced the sensor, added shielded cables, swapped the AD module with a new one, and pulled a separate 24V power line, but it still fluctuates. Even weirder, it fluctuates badly during daytime peak power usage, but is much more stable when working overtime at night. We've stopped the line three times to troubleshoot, and production is pushing us every day. The boss asks if I wrote the HMI program wrong... My program just reads the channel with FROM and converts, and I've set filtering. Now I suspect it's interference from the workshop's inverters or a grounding problem. Has anyone encountered a similar situation? Please advise on troubleshooting directions. Thanks a lot!
Mark Zhang asked 2026-11-02 09:07 👁️ 17 views 5 answer(s)
5 Answers
Upvotes
L
2026-11-03 06:10
Don't panic if your ranking on the international site drops. It's most likely a penalty for keyword stuffing in the title. Change the title to a natural word order, embed long-tail keywords in the description, and it should recover within two weeks.
#1 Lin Jiaxin
Upvotes
D
2026-11-03 08:17
We've encountered this situation too, and it turned out to be the ejector pin material. We switched from ordinary ejector pins to SKD61 nitrided ones, and the lifespan doubled.
#2 David Chen
Upvotes
Y
2026-11-02 10:57
Referrals from old customers are indeed the best channel, but you also need an online presence. You can start with a company homepage + industry Q&A + precise keywords, and accumulate slowly at low cost.
#3 Ye Jing
Upvotes
T
2026-11-03 00:56
A difference of a few kilograms in customs gross weight is very common. Generally, if the error is within 0.5%, customs won't hold it up. If they really nitpick, just have the freight forwarder issue a weighing record as proof. We often handle it this way.
#4 Tony Wang
Upvotes
L
Liang Jing ✓ Best Answer
2026-11-03 03:31
Siemens and ABB DP communication often disconnects, mostly due to termination resistors and grounding issues. Route the communication cable separately, add termination resistors at both ends, and ground the shield at one end only. This basically solves the problem.
#5 Liang Jing