In mold cooling design, the temperature field solver is only as good as its boundary conditions. On the plastic side, the heat flux entering the mold is governed by the melt-to-wall temperature difference and the interfacial condition; in practice we treat the polymer-to-steel interface as a specified heat flux or a contact resistance, because the cycle-averaged heat input is what drives the steady periodic temperature field. Getting this wrong—say, assuming perfect contact and uniform flux—skews the predicted hot spots near gates and ribs, which is exactly where we later fight warpage and sink marks.

On the water side, the convective heat transfer coefficient h is the number that matters, and it is not a constant. For typical turbulent flow in a 10–12 mm cooling channel at 2–4 m/s, h lands in the range of roughly 5,000–15,000 W/m²·K depending on water temperature and channel diameter; below Reynolds 10,000 you drop into transition and h falls off fast. Use the Dittus-Boelter correlation for straight runs, but switch to a local correlation at bends, baffles, and bubblers, where the flow separates and the effective h can vary by a factor of two along the circuit. Series-connected channels also mean downstream water is warmer—account for bulk temperature rise, or the last cavities in the loop will run hotter than the first.

For the mold exterior, natural convection to air (h ≈ 5–10 W/m²·K) and radiation are usually lumped into an effective coefficient; don't ignore them on small cores or slides with limited cooling. When setting up the analysis, apply h per channel segment rather than one global value, and check that the predicted steel surface temperature stays within about 10–20°C of your target before cutting steel. For more mold sourcing and design reference information, visit MoldSo at www.moldso.com.